Escolha sua fonte:
 Arimo
 Merriweather
 Mukta Malar
 Open Sans Condensed
 Rokkitt
 Source Sans Pro
 Login


 Português 
 Français 
 English 
 Español 

[Valid RSS] RSS
bar

Banco de dados - (CIANE)

Descrição deste banco de dados documental (Site da CIANE)
Atualmente 3109 fichas
Canal do YouTube (tutorial)

https://ciane.net/id=3001

Criado em : 20 Aug 2018
Alterado em : 30 Oct 2019

 Modificar esta ficha
Siga este link somente se você tiver um palavra chave de editor!


Compartilhar: Facebook logo   Tweeter logo   Fácil

Nota bibliográfica (sem autor) :

An inflatable ergonomic 3-chamber fundal pressure belt to assist vaginal delivery. Int J Gynaecol Obstet. 2013

Autores :

Acanfora L, Rampon M, Filippeschi M, Marchi M, Montisci M, Viel G, Cosmi E.

Ano de publicação :

2013

URL(s) :

https://obgyn.onlinelibrary.wiley.com/doi/abs/10.1…
https://doi.org/10.1016/j.ijgo.2012.07.025

Résumé (français)  :

Évaluer si Baby-guard, un nouveau dispositif médical doté d’une ceinture abdominale gonflable ergonomique à 3 chambres, peut réduire les complications associées à un accouchement par voie vaginale.

METHODES :
Une étude prospective randomisée et contrôlée menée auprès de 80 femmes enceintes en étude à l’aveugle ayant accouché à terme a été menée à l’hôpital San Giuseppe, à Empoli, en Italie. Dans le groupe d’étude (n = 40), la ceinture abdominale a été gonflée à des pressions thérapeutiques optimales. Dans le groupe témoin (n = 40), la ceinture abdominale a été gonflée à des pressions minimales non thérapeutiques. Les facteurs liés aux complications maternelles, fœtales et du travail lors de l’accouchement vaginal ont été évalués.

RÉSULTATS :
Comparativement au groupe témoin, les femmes du groupe d’étude ont présenté une incidence plus faible de lacérations périnéales et cervicales (P0,001) ; utilisation réduite de la manœuvre de Kristeller (P0.001) ; durée plus courte du deuxième stade du travail (P0.001) ; moins de fatigue psychologique et physique (P0,001) ; moins de demandes maternelles d’accouchement par césarienne pendant le travail (P0.001) ; moins d’extractions sous vide (P0,01) ; et moins d’accouchements par césarienne (P0.02). Aucune admission en unité de soins intensifs néonatals n’a été enregistrée dans le groupe d’étude contre 7 dans le groupe témoin (P0,012).

CONCLUSION :
L’utilisation du système de ceinture abdominale gonflable ergonomique à 3 chambres a permis de réduire l’incidence des risques liés au travail vaginal.

Abstract (English)  :

To evaluate whether Baby-guard-a new medical device with an ergonomic 3-chamber inflatable abdominal belt-can reduce complications associated with vaginal delivery.

METHODS:
A randomized controlled single blind prospective study of 80 pregnant women delivering at term was conducted at San Giuseppe Hospital, Empoli, Italy. In the study group (n=40), the abdominal belt was inflated to optimal therapeutic pressures. In the control group (n=40), the abdominal belt was inflated to minimal, non-therapeutic pressures. Factors relating to maternal, fetal, and labor complications during vaginal delivery were evaluated.

RESULTS:
Compared with the control group, women in the study group experienced a lower incidence of perineal and cervical lacerations (P0.001); reduced use of the Kristeller maneuver (P0.001); shorter duration of the second stage of labor (P0.001); less psychologic and physical fatigue (P0.001); fewer maternal requests for cesarean delivery during labor (P0.001); fewer vacuum extractions (P0.01); and fewer cesarean deliveries (P0.02). No neonatal intensive care unit admissions were recorded in the study group versus 7 in the control group (P0.012).

CONCLUSION:
Use of the ergonomic 3-chamber inflatable abdominal belt system reduced the incidence of risks associated with vaginal labor

Sumário (português)  :

Resumen (español)  :

Comentários :

Argument (français) :

L’utilisation du système de ceinture abdominale gonflable ergonomique à 3 chambres a permis de réduire l’incidence des risques liés au travail vaginal.

Argument (English):

Use of the ergonomic 3-chamber inflatable abdominal belt system reduced the incidence of risks associated with vaginal labor.

Argumento (português):

O uso do sistema de cinta abdominal inflável de 3 câmaras ergonômico reduziu a incidência de riscos associados ao trabalho vaginal.

Argumento (español):

Palavras-chaves :

➡ expressão abdominal

Autor da esta ficha :

Alison Passieux — 20 Aug 2018
➡ última atualização : Alison Passieux — 30 Oct 2019

Discussão (exibir apenas português)
 
➡ Reservado para usuários identificados



 Li a carta de discussões e aceito as condições (leia as diretrizes)

barre

Efectuar uma nova consulta especialista --- Outro pedido simples

Criação de uma ficha --- Importar registros

Gerenciamento de usuários --- Fazer backup do banco de dados --- Contato

bar

Esta base de dados criada pela Alliance francophone pour l'accouchement respecté (AFAR) é gerida
pela Collectif interassociatif autour de la naissance (CIANE, https://ciane.net).
Ele é alimentado pelas contribuições de voluntários interessados ​​em compartilhar informações científicas.
Se você aprovar este projeto, você pode nos ajudar de várias maneiras:
(1) tornar-se um colaborador com base nisso, se você tem um pouco experiência na literatura científica
(2) ou apoio financeiro CIANE (veja abaixo)
(3) ou tornar-se um membro da outra associação afiliada à CIANE.
Faça login ou crie uma conta para seguir as alterações ou se tornar um editor.
Contato bibli(arobase)ciane.net para mais informações.

Valid CSS! Valid HTML!
Doar para a CIANE (clique em “Faire un don”) nos ajudará a manter e desenvolver sites e bancos de dados
públicos para o apoio das decisões informadas dos pais e cuidadores com relação ao parto